Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Braz. j. pharm. sci ; 47(2): 363-371, Apr.-June 2011. ilus, tab
Article in English | LILACS | ID: lil-595824

ABSTRACT

A liquid-liquid extraction (LLE) combined with high-performance liquid chromatography-diode array detection method for simultaneous analysis of four chemically and structurally different antineoplastic drugs (cyclophosphamide, doxorubicin, 5-fluorouracil and ifosfamide) was developed. The assay was performed by isocratic elution, with a C18 column (5 µm, 250 x 4.6 mm) and mobile phase constituted by water pH 4.0- acetonitrile-methanol (68:19:13, v/v/v), which allowed satisfactory separation of the compounds of interest. LLE, with ethyl acetate, was used for sample clean-up with recoveries ranging from 60 to 98 percent. The linear ranges were from 0.5 to 100 µg mL-1, for doxorubicin and 1 to 100 µg mL-1, for the other compounds. The relative standard deviations ranged from 5.5 to 17.7 percent. This method is a fast and simple alternative that can be used, simultaneously, for the determination of the four drugs in plasma, with a range enabling quantification of the drugs in pharmacokinetics, bioequivalence and therapeutic drug-monitoring studies.


Um método de extração líquido-líquido (ELL) combinado com cromatografia líquida de alta eficiência-detector de arranjo de diodos foi desenvolvido para análise simultânea de quatro fármacos antineoplásicos quimicamente e estruturalmente diferentes (ciclofosfamida, doxorrubicina, fluoruracila e ifosfamida). O estudo foi realizado sob condições isocráticas, com coluna C18 (5µm, 250 x 4.6 mm) e fase móvel constituída por água pH 4.0-acetonitrila-metanol (68:19:13, v/v/v), que permitiu separação satisfatória dos analitos de interesse. A ELL, com acetato de etila, foi utilizada para limpeza da amostra, com recuperação variando de 60 a 98 por cento. As faixas foram lineares de 0,5 a 100 µg mL-1 para doxorrubicina e 1 a 100 µg mL-1 para os outros compostos. O desvio padrão relativo variou de 5,5 a 17,7 por cento. Este método é uma alternativa rápida e simples que pode ser usado, simultaneamente, para a determinação dos quatro fármacos em plasma, com uma faixa que permite quantificá-los em estudos de farmacocinética, bioequivalência e monitorização terapêutica.


Subject(s)
Adult , Animals , Male , Rats , Antineoplastic Agents/analysis , Antineoplastic Agents/pharmacokinetics , Antineoplastic Agents/blood , Biological Assay , Drug Screening Assays, Antitumor
2.
Braz. j. pharm. sci ; 46(4): 769-776, Oct.-Dec. 2010. graf, tab
Article in English | LILACS | ID: lil-622877

ABSTRACT

Nicotine is a major addictive compound in cigarettes and is rapidly and extensively metabolized to several metabolites in humans, including urinary cotinine, considered a biomarker due to its high concentration compared to other metabolites. The aim of this study was to develop a single method for determination of urinary cotinine, in active and passive smokers, by gas chromatography with a nitrogen phosphorus detector (GC-NPD). Urine (5.0 mL) was extracted with 1.0 mL of sodium hydroxide 5 mol L-1, 5.0 mL of chloroform, and lidocaine used as the internal standard. Injection volume was 1 ìL in GC-NPD. Limit of quantification was 10 ng mL-1. Linearity was evaluated in the ranges 10-1000 ng mL-1 and 500-6000 ng mL-1, with determination coefficients of 0.9986 and 0.9952, respectively. Intra- and inter-assay standard relative deviations were lower than 14.2 %, while inaccuracy (bias) was less than +11.9%. The efficiency of extraction was greater than 88.5%. Ruggedness was verified, according to Youden's test. Means of cotinine concentrations observed were 2,980 ng mL-1 for active smokers and 132 ng mL-1, for passive smokers. The results revealed that satisfactory chromatographic separation between the analyte and interferents was obtained with a ZB-1 column. This method is reliable, precise, linear and presented ruggedness in the range evaluated. The results suggest that it can be applied in routine analysis for passive and active smokers, since it is able to quantify a wide range of cotinine concentrations in urine.


A nicotina é uma substância presente no cigarro capaz de causar dependência, sendo biotransformada em vários metabólitos nos seres humanos, dentre eles a cotinina urinária, que é considerada um indicador biológico de exposição à nicotina, devido a suas altas concentrações, comparado a outras matrizes. Assim, o objetivo deste estudo foi desenvolver um único método para determinação de cotinina urinária, em amostras de urina de fumantes ativos e passivos, através de cromatografia em fase gasosa com detector de nitrogênio- fósforo (CG-DNF). Para o preparo de amostras foram utilizados 5 mL de urina, 1 mL de hidróxido de sódio 5 mol L-1, 5 mL de clorofórmio, tendo como padrão interno a lidocaína. Na faixa de concentrações de 10-1000 ng mL-1 e 500- 6000 ng mL-1, o coeficiente de determinação foi 0,9986 e 0,9952, respectivamente e, o limite de quantificação foi 10 ng mL-1. A precisão intra- e interensaio apresentou desvio padrão relativo (%) menor que 14,2% e a inexatidão foi menor que +11,9%, com uma eficiência de extração de 88,5%. O método apresentou robustez, de acordo com o teste de Youden. As concentrações médias de cotinina observadas foram 2980 ng mL-1, para fumantes ativos e 132 ng mL-1, para fumantes passivos. Os resultados sugerem que o método é confiável, preciso, linear e apresentou robustez, na faixa avaliada, podendo ser aplicado na rotina para análises de amostras de fumantes ativos e passivos, pois é capaz de quantificar uma ampla faixa de concentrações de cotinina urinária.


Subject(s)
Phosphorus Compounds , Nitrogen Compounds , Cotinine/urine , Cotinine , Chromatography, Gas/methods , Smoking/urine , Tobacco Smoke Pollution , Urine/chemistry , Laboratory and Fieldwork Analytical Methods/methods , Toxicology/methods
SELECTION OF CITATIONS
SEARCH DETAIL